View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0001471 | Core Components | public | 2011-02-03 15:15 | 2012-08-20 17:21 | |
Reporter | bill packard | Assigned To | Randy Armstrong | ||
Priority | normal | Severity | minor | Reproducibility | always |
Status | assigned | Resolution | open | ||
Summary | 0001471: Missing condition in reference action (StartServices) in OPC COM ProxyStub merge module | ||||
Description | The OPC COM ProxyStub merge module contains a service entry in the (Module)InstallExecuteSequence table, which uses the standard action StartServices as a basis action. The entry for StartServices does not contain a condition. This causes a warning message when the merge module is imported using WiX. In the final MSI the StartServices action has a condition of: VersionNT, the reference action in the merge module should contain the same condition. | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2011-02-03 15:15 | bill packard | New Issue | |
2012-08-20 17:20 |
|
Status | new => assigned |
2012-08-20 17:20 |
|
Assigned To | => Randy Armstrong |
2012-08-20 17:21 |
|
Note Added: 0004001 |