View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0008201 | Part 84: UAFX Profiles | Spec | public | 2022-08-16 13:14 | 2022-09-21 22:11 |
Reporter | Brian Batke | Assigned To | Greg Majcher | ||
Priority | high | Severity | major | Reproducibility | N/A |
Status | closed | Resolution | fixed | ||
Summary | 0008201: Missing CU for required, supported data types for C2C application exchange | ||||
Description | Mantis requirement 5076, developed by the FA/PA Requirements team, specifies the minimum common data types that all controllers need to support for C2C application-level exchange (and the comments have further explanation). Part 84 is missing any CUs to enable meeting this requirement. | ||||
Tags | No tags attached. | ||||
|
Requirement 5076 states that controllers must support a limited set of datatypes. Requirement 5077 states that controllers may support any datatype. This combination was intended to allow any datatype support in controllers, but require a minimum set for interoperability of application data. A new conformance unit will be written to mandate the minimum datatype support for application data (i.e., input and output data). |
|
The following wording was approved during an AWG meeting. UAFX FunctionalEntity Datatype Support UAFX FunctionalEntities shall support Boolean, SByte, Byte, Int16, UInt16, Int32, UInt32, Float datatypes for InputData and OutputData. |
|
The new conformance unit was added as mandatory in the FunctionalEntity facet. |
|
Wording was updated to include ConfigurationData. UAFX FunctionalEntity Datatype Support UAFX FunctionalEntities shall support Boolean, SByte, Byte, Int16, UInt16, Int32, UInt32, Float datatypes for InputData, OutputData, and ConfigurationData. |
|
CU added to Part 84 and profile database. Agreed to in AWG call. |
|
As worded, the CU may be interpreted that all FEs need to support input, output, and config. That can be fixed with a simple modification. Additionally it has been questioned whether this belongs at the FE or AC level. |
|
The CU needs to be rewritten and retargeted. If we write it as is and locate it in the FunctionalEntity, all implementations (even temperature sensors) would need to support all these datatypes. |
|
Nobody felt that the conformance unit was misleading regarding the input, output, and configuration data. We decided to reject that feedback. |
|
Discussed new feedback and addressed it in the AWG meeting. |
Date Modified | Username | Field | Change |
---|---|---|---|
2022-08-16 13:14 | Brian Batke | New Issue | |
2022-08-17 13:36 | Greg Majcher | Assigned To | => Greg Majcher |
2022-08-17 13:36 | Greg Majcher | Status | new => assigned |
2022-08-17 15:30 | Greg Majcher | Note Added: 0017328 | |
2022-08-24 15:20 | Greg Majcher | Note Added: 0017386 | |
2022-08-26 14:49 | Greg Majcher | Status | assigned => resolved |
2022-08-26 14:49 | Greg Majcher | Resolution | open => fixed |
2022-08-26 14:49 | Greg Majcher | Note Added: 0017408 | |
2022-08-31 14:12 | Greg Majcher | Note Added: 0017476 | |
2022-08-31 14:13 | Greg Majcher | Status | resolved => closed |
2022-08-31 14:13 | Greg Majcher | Note Added: 0017477 | |
2022-09-08 14:46 | Greg Majcher | Status | closed => feedback |
2022-09-08 14:46 | Greg Majcher | Resolution | fixed => reopened |
2022-09-08 14:46 | Greg Majcher | Note Added: 0017575 | |
2022-09-08 18:05 | Bob Lattimer | Note Edited: 0017575 | |
2022-09-09 17:25 | Greg Majcher | Note Added: 0017611 | |
2022-09-21 22:10 | Greg Majcher | Status | feedback => resolved |
2022-09-21 22:10 | Greg Majcher | Note Added: 0017781 | |
2022-09-21 22:10 | Greg Majcher | Resolution | reopened => fixed |
2022-09-21 22:11 | Greg Majcher | Status | resolved => closed |
2022-09-21 22:11 | Greg Majcher | Note Added: 0017782 |