View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0009368 | 10000-014: PubSub | Spec | public | 2024-01-21 14:46 | 2024-03-20 22:22 |
Reporter | Zbynek Zahradnik | Assigned To | Matthias Damm | ||
Priority | normal | Severity | minor | Reproducibility | always |
Status | closed | Resolution | fixed | ||
Product Version | 1.05.03 | ||||
Fixed in Version | 1.05.04 RC1 | ||||
Summary | 0009368: MQTT standard message properties configuration does not differentiate between data and metadata | ||||
Description | This issue relates to "7.3.5.8 Message header" and "Table 181 – OPC UA MQTT standard message property configuration". It is likely that at least some of the properties (such as Message Expiry Interval) will need to differ between data and metadata messages on the same writer group/dataset writer. But there appears to be just one common setting for them. | ||||
Tags | No tags attached. | ||||
Commit Version | 1.05.04 RC | ||||
Fix Due Date | |||||
|
Added the following additional definition: If the property is for metadata messages, the Name of the QualifiedName is constructed from a metadata prefix and the MQTT property name with the following syntax. |
|
Agreed to changes edited in Dallas F2F. |
Date Modified | Username | Field | Change |
---|---|---|---|
2024-01-21 14:46 | Zbynek Zahradnik | New Issue | |
2024-02-27 17:33 | Jim Luth | Assigned To | => Matthias Damm |
2024-02-27 17:33 | Jim Luth | Status | new => assigned |
2024-03-17 23:58 | Matthias Damm | Status | assigned => resolved |
2024-03-17 23:58 | Matthias Damm | Resolution | open => fixed |
2024-03-17 23:58 | Matthias Damm | Note Added: 0020920 | |
2024-03-20 22:22 | Jim Luth | Status | resolved => closed |
2024-03-20 22:22 | Jim Luth | Fixed in Version | => 1.05.04 RC1 |
2024-03-20 22:22 | Jim Luth | Commit Version | => 1.05.04 RC |
2024-03-20 22:22 | Jim Luth | Note Added: 0020988 |