View Issue Details

IDProjectCategoryView StatusLast Update
001039530110: PowerlinkImplementation Bugpublic2025-06-25 15:46
ReporterWolfgang Mahnke Assigned To 
PrioritynormalSeverityminorReproducibilityhave not tried
Status newResolutionopen 
Summary0010395: Issues with NodeSet File
Description
  1. TopologyElementType > ConnectionPointType > PowerlinkConnectionPointType > PowerlinkCnConnectionPointType > ParameterSet > NMT_EPLVersion_U8 is an override with wrong ValueRank (-1 instead of 1)

  2. Same for PowerlinkMnConnectionPointType

  3. BaseVariableType > BaseDataVariableType > PowerlinkRecordType > NMT_ParameterStorage_Type has DataType BaseDataType but super type has DataType Byte.
    Set DataType to Byte

TagsNo tags attached.

Activities

There are no notes attached to this issue.

Issue History

Date Modified Username Field Change
2025-06-25 15:46 Wolfgang Mahnke New Issue