View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0002638 | Core Components | public | 2013-10-02 10:10 | 2013-11-11 07:44 | |
Reporter | Henning Bjorgo | Assigned To | |||
Priority | normal | Severity | crash | Reproducibility | always |
Status | assigned | Resolution | open | ||
Summary | 0002638: OPC Comliance Test 2.00 crashes when adding items from server to HDA test. | ||||
Description | In the OPC Compliance Test 2.00 tool, when testing HDA, adding a OPC HDA server is OK, but when adding items, the whole program crashes. Sometimes it hangs when pressing the "Select item(s)" button, sometimes it crashes when navigating the items tree view, and sometimes it crashes when starting the test after adding some items. I have not been able to run a test for HDA. Running on: Windows Server 2008, SP2, x64. | ||||
Additional Information | This is the Microsoft error message: Problem signature: Read our privacy statement: | ||||
Tags | No tags attached. | ||||
|
Can you please clarify the version of the HDA plug-in, which you can find in the HELP...ABOUT dialog. It should look something like this: OPC Historical Data Access 1.2 Compliance Test: |
|
I'm using this: GUI Version: 2.15.0.1152 OPC Alarm and Events 1.1 Compliance Test: |
Date Modified | Username | Field | Change |
---|---|---|---|
2013-10-02 10:10 | Henning Bjorgo | New Issue | |
2013-11-08 17:25 |
|
Note Added: 0005089 | |
2013-11-08 17:25 |
|
Assigned To | => Nathan Pocock |
2013-11-08 17:25 |
|
Status | new => assigned |
2013-11-11 07:44 | Henning Bjorgo | Note Added: 0005099 |