View Issue Details

IDProjectCategoryView StatusLast Update
000589230120: IO-LinkImplementation Bugpublic2023-02-10 18:46
ReporterMartin Lang Assigned ToJoachim Stilz 
PrioritynormalSeverityminorReproducibilityhave not tried
Status resolvedResolutionfixed 
Target VersionV1.01 
Summary0005892: Fix wrong AccessLevel for DI inherited properties
Description

Within the Nodeset file published at 2018-12-01T00:00:00, V1.0 some DI derived variable nodes has wrong AccessLevel 3 (CurrentRead|CurrentWrite).
Since DI specifies CurrentRead the IO-Link Nodeset file shall correct this at least for this NodeIds.

Additional Information
  1. <UAVariable DataType="String" ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=6140" BrowseName="2:HardwareRevision" AccessLevel="3">
    to
    <UAVariable DataType="String" ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=6140" BrowseName="2:HardwareRevision">

  2. <UAVariable DataType="LocalizedText" ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=6129" BrowseName="2:Manufacturer" AccessLevel="3">
    to
    <UAVariable DataType="LocalizedText" ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=6129" BrowseName="2:Manufacturer">

  3. <UAVariable DataType="LocalizedText" ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=6139" BrowseName="2:Model" AccessLevel="3">
    to
    <UAVariable DataType="LocalizedText" ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=6139" BrowseName="2:Model">

  4. <UAVariable DataType="String" ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=6141" BrowseName="2:SoftwareRevision" AccessLevel="3">
    to
    <UAVariable DataType="String" ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=6141" BrowseName="2:SoftwareRevision">

TagsNo tags attached.

Relationships

related to 0007416 confirmedDeepak Yadav Support for IO Link Wireless Extensions 

Activities

Joachim Stilz

2021-02-09 10:02

viewer   ~0013693

Will be corrected in Release 1.00.01.

Joachim Stilz

2021-02-17 11:24

viewer   ~0013733

Last edited: 2021-02-17 11:28

For the properties SerialNumber, SoftwareRevision, HardwareRevision, Model, Manufacturer and the variable DeviceHealth it should be indicated in the Spec., that they are read-only. --> fixed in Rev. 1.00.01

Issue History

Date Modified Username Field Change
2020-08-14 14:16 Martin Lang New Issue
2021-02-09 10:02 Joachim Stilz Note Added: 0013693
2021-02-09 12:50 Joachim Stilz Assigned To => Joachim Stilz
2021-02-09 12:50 Joachim Stilz Status new => assigned
2021-02-09 12:51 Joachim Stilz Status assigned => confirmed
2021-02-09 12:54 Joachim Stilz Status confirmed => resolved
2021-02-17 11:24 Joachim Stilz Note Added: 0013733
2021-02-17 11:28 Joachim Stilz Note Edited: 0013733
2023-02-10 17:02 Martin Lang Relationship added related to 0007416
2023-02-10 18:31 Martin Lang Resolution open => fixed
2023-02-10 18:46 Martin Lang Target Version => V1.01