Description

The ADI NodeSet defines some finite state machines. Its states have the property StateNumber and its transitions the property TransitionNumber. A lot (20+54) of the BrowseNames of these properties have an index representing the ADI namespace. But it should have no namespace index (meaning index 0, the OPC UA namespace), because these properties are defined by the ObjectType StateType and TransitionType which are in OPC UA Namespace (Index 0).

Steps To Reproduce

Open SiOME (Siemens OPC UA Modeling Editor), import DI and ADI NodeSets, validate.

Additional Information

Example nodes: SelectExecutionCyle (ADI;i=10201) with ADI:StateNumber (ADI;i=10202) and StoppedToResettingTransition (ADI;i=10082) with ADI:TransitionNumber (ADI:i=10083).