View Issue Details

IDProjectCategoryView StatusLast Update
000877010020: Analyzer Device Integration (ADI)Implementation Bugpublic2023-04-03 14:38
ReporterHerbert Oppmann Assigned To 
PrioritynormalSeveritymajorReproducibilityalways
Status newResolutionopen 
Product Version1.01 
Summary0008770: NodeSet: Invalid override on subtype
Description

The VariableType ChemometricModelType has a property "<User defined Output#>" with a ModellingRule MandatoryPlaceholder. The derived VariableType MVAModelType overrides this property with a ModellingRule OptionalPlaceholder. This is not allowed (see OPC UA specification Part 3, chapter "Subtyping Rules for Properties of ModellingRules").

Steps To Reproduce

Open SiOME (Siemens OPC UA Modeling Editor), import DI and ADI NodeSets, validate.

TagsNo tags attached.

Activities

There are no notes attached to this issue.

Issue History

Date Modified Username Field Change
2023-04-03 14:38 Herbert Oppmann New Issue