| 0008771 | 30040: AutomationML | Implementation Bug | public | 2023-04-03 15:26 | 2023-04-04 05:20 |
| Reporter | Herbert Oppmann | Assigned To | miriamschleipen | ||
| Priority | normal | Severity | major | Reproducibility | always |
| Status | acknowledged | Resolution | open | ||
| Product Version | 1.00.00 | ||||
| Summary | 0008771: [AutomationML] NodeSet has missing DataType attributes | ||||
| Description | Opc.Ua.AMLLibraries.NodeSet2.xml: Some properties are lacking the XML attribute "DataType" and therefore the schema default "i=24" (BaseDataType) takes effect: CAEXSchemaVersion (i=341), FileName (i=340), ID (i=2, 5, 8, 11, 14, 17, 20) and Version (i=3, 6, 9, 12, 15, 18, 21, 339) (all NodeIds are in namespace of AMLLibraries). | ||||
| Steps To Reproduce | Open SiOME (Siemens OPC UA Modeling Editor), import Opc.Ua.AMLBaseTypes.NodeSet2.xml and Opc.Ua.AMLLibraries.NodeSet2.xml, validate. | ||||
| Tags | No tags attached. | ||||
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2023-04-03 15:26 | Herbert Oppmann | New Issue | |
| 2023-04-04 05:20 | miriamschleipen | Assigned To | => miriamschleipen |
| 2023-04-04 05:20 | miriamschleipen | Status | new => acknowledged |