View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0008960 | 30200: Commercial Kitchen Equipment | Implementation Bug | public | 2023-05-12 17:32 | 2023-05-12 17:32 |
Reporter | Herbert Oppmann | Assigned To | |||
Priority | normal | Severity | minor | Reproducibility | always |
Status | new | Resolution | open | ||
Summary | 0008960: Invalid override of components of CombiSteamerParameterType | ||||
Description | CombiSteamerParameterType (ns=1;i=1010, line 3614ff) has (amongst others) the components ActualInternalCoreTemperature<No.> (ns=1;i=6115, line 3729ff) with ModellingRule OptionalPlaceholder and ActualTemperatureChamber<No.> (ns=1;i=6107, line 3774ff) with ModellingRule MandatoryPlaceholder. In CombiSteamerDeviceType (ns=1;i=1011) the component CombiSteamer (ns=1;i=5007) of type CombiSteamerParameterType has these two sub-components (ns=1;i=6151 and ns=1;i=6154) with ModellingRule Mandatory. But it is not allowed to override OptionalPlaceholder / MandatoryPlaceholder with Mandatory. Btw. the naming seems inconsistent. In some DeviceTypes the object of type XXXParameterType is called as the device, and in some it is called "Parameters". | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2023-05-12 17:32 | Herbert Oppmann | New Issue |