View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0009222 | 30120: IO-Link | [UA] IO-Link Wireless | public | 2023-10-27 14:09 | 2023-10-27 14:10 |
Reporter | Martin Lang | Assigned To | |||
Priority | normal | Severity | minor | Reproducibility | have not tried |
Status | new | Resolution | open | ||
Summary | 0009222: Add ObjectType for IO-Link Wireless Bridge | ||||
Description | Define an ObjectType for IO-Link Wireless Bridge. The ObjectInstanceDeclaration should be placed below the IO-Link Wireless Port ObjectType with the modelling rule OptionalPlaceholder. Currently, there is no clear definition from SMI on how to evaluate the Bridge Standalone Mode. There are no new IO-Link Master events that signal in which mode the Bridge/Port is running. The latest proposal from the SMI Working Group was to evaluate this by comparing VendorId and DeviceId, but this is not feasible in a real device in the field since some OPC UA IO-Link Masters already in the field do not know about newer Bridge VendorId/DeviceId. The SMI specification should provide a generic way. Until a solution is provided, OPC UA for IO-Link cannot include this new ObjectType for Bridges. | ||||
Tags | No tags attached. | ||||
related to | 0008622 | assigned | Deepak Yadav | Add IO-Link Wireless System Extensions to companion specification |
Date Modified | Username | Field | Change |
---|---|---|---|
2023-10-27 14:09 | Martin Lang | New Issue | |
2023-10-27 14:09 | Martin Lang | Relationship added | related to 0008622 |
2023-10-27 14:10 | Martin Lang | Description Updated |