000968330110: PowerlinkImplementation Bugpublic2024-07-30 10:40
ReporterPeter Schuster Assigned To 
PrioritynormalSeverityminorReproducibilityalways
Status newResolutionopen 
Summary0009683: Invalid Value and ValueRank for variable NMT_EPLVersion_U8 in Opc.Ua.POWERLINK.NodeSet2.xml
Description

The Opc.Ua.POWERLINK.NodeSet2.xml has an invalid definition of variable NMT_EPLVersion_U8 (node id ns=1;i=682).

The ValueRank and Value are set to array, but the type itself is a single byte.
See also https://reference.opcfoundation.org/POWERLINK/v100/docs/6.2

The issue is present in the private (https://github.com/OPCF-Members/UA-NodeSet) and public (https://github.com/OPCFoundation/UA-Nodeset) github repositories

TagsUANodeSet

Activities

Peter Schuster

2024-07-30 10:40

reporter   ~0021518

The proposed fix is in pull request https://github.com/OPCF-Members/UA-NodeSet/pull/24

Issue History

Date Modified Username Field Change
2024-07-30 10:36 Peter Schuster New Issue
2024-07-30 10:36 Peter Schuster Tag Attached: UANodeSet
2024-07-30 10:40 Peter Schuster Note Added: 0021518