Summary0009873: 7.2.3.6 Example for CRC Signature Gives Wrong Length for SafetyData
Description

The SafetyData length for the example data (Int32 var1, UInt32 var2, UInt16 var3, Int16 var4, Boolean var5) is 13 octets, not 12 octets as written. The length of the STrailer without the CRC is 21 octets, not 16 octets as written. The total length is therefore 13 + 21 = 33 octets, not 34 octets as written.

TagsNo tags attached.
Commit Version

Activities

There are no notes attached to this issue.

Issue History

Date Modified Username Field Change
2024-10-08 13:22 Christian Eitner New Issue
2024-10-08 13:22 Christian Eitner Status new => assigned
2024-10-08 13:22 Christian Eitner Assigned To => Christian Eitner