View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0010118 | Part 81: UAFX Connecting Devices and Information Model | Spec | public | 2025-01-28 12:28 | 2025-01-28 15:19 |
Reporter | Thomas Schreck | Assigned To | Paul Hunkar | ||
Priority | normal | Severity | minor | Reproducibility | N/A |
Status | closed | Resolution | fixed | ||
Fixed in Version | 1.00.03 | ||||
Summary | 0010118: SerialNumber and ProductInstanceUri spec requirement is different from profile | ||||
Description | Profile requires SerialNumber or ProductInstanceUri whereas Part 81 requires always both to be present on Assets directly referenced from Assets folder. | ||||
Tags | No tags attached. | ||||
|
Updated description of SerialNumber and ProductInstanceUri to indicate that one of them is required (both is optional) but both are not always required. |
|
reviewed in call - agreed to changes and closed issue |
Date Modified | Username | Field | Change |
---|---|---|---|
2025-01-28 12:28 | Thomas Schreck | New Issue | |
2025-01-28 15:17 | Paul Hunkar | Assigned To | => Paul Hunkar |
2025-01-28 15:17 | Paul Hunkar | Status | new => assigned |
2025-01-28 15:19 | Paul Hunkar | Status | assigned => resolved |
2025-01-28 15:19 | Paul Hunkar | Resolution | open => fixed |
2025-01-28 15:19 | Paul Hunkar | Fixed in Version | => 1.00.03 |
2025-01-28 15:19 | Paul Hunkar | Note Added: 0022342 | |
2025-01-28 15:19 | Paul Hunkar | Status | resolved => closed |
2025-01-28 15:19 | Paul Hunkar | Note Added: 0022343 |