| Description | CMPWG Oct-1-2015: The description for the Base Info Custom Type System conformance unit is very confusing, specifically the 2nd sentence: "Supporting this conformance unit does not require that a Server exposes the OPC UA Object, Variable, Reference, or Data Types, unless the Server implements User types." Some questions: Does the 2nd and 3rd sentence (of the overall description) conflict? | ||||
| Tags | No tags attached. | ||||
| Commit Version | |||||
| Fix Due Date | |||||
|
|
1) change User Types into user defined types |
|
|
fixed in "OPC UA Part 7 - Profiles RC 1.03.21 Specification.docx" |
|
|
Agreed to fixes already published in 1.03 |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2015-10-01 16:23 |
|
New Issue | |
| 2015-11-10 18:00 | Karl Deiretsbacher | Note Added: 0006444 | |
| 2015-11-10 18:00 | Karl Deiretsbacher | Assigned To | => Karl Deiretsbacher |
| 2015-11-10 18:00 | Karl Deiretsbacher | Status | new => assigned |
| 2015-11-10 19:32 | Jim Luth | Target Version | => 1.03 |
| 2015-11-11 06:49 | Karl Deiretsbacher | Note Added: 0006448 | |
| 2015-11-11 06:49 | Karl Deiretsbacher | Status | assigned => resolved |
| 2015-11-11 06:49 | Karl Deiretsbacher | Fixed in Version | => 1.03 |
| 2015-11-11 06:49 | Karl Deiretsbacher | Resolution | open => fixed |
| 2016-03-15 15:07 | Jim Luth | Note Added: 0006791 | |
| 2016-03-15 15:07 | Jim Luth | Status | resolved => closed |