View Issue Details

IDProjectCategoryView StatusLast Update
000360510000-013: AggregatesSpecpublic2016-11-22 16:18
ReporterRod Stein Assigned ToRod Stein  
PrioritynormalSeverityminorReproducibilityhave not tried
Status closedResolutionfixed 
Product Version1.03 
Summary0003605: The Aggregate Number of Transitions has some errors
Description

The heading in the A.22.1 has an interval of 00:00:05.000 but the tables have an interval of 00:00:16.000.
The table for Historian1 has the wrong value for the 12:01:20.000 interval. It should be 2 not 1.
The first interval for all Historian examples needs to be 1. The first good value at the start of the request is always counted as a transition.

From forum https://opcfoundation.org/forum/opc-ua-standard/number-of-transitions-aggregate-clarifications/

TagsNo tags attached.
Commit Version

Relationships

related to 0003611 assignedArchie Miller NodeSets, XSDs and Generated Code The Aggregate Number of Transitions has some errors 

Activities

Rod Stein

2016-11-15 21:19

developer   ~0007320

Fixed in Part 13 Draft 0

The heading in the A.22.1 has an interval of 00:00:16.000.

The table for Historian1 has the wrong value for the 12:01:20.000 interval. It is now 2 not 1.

The first interval for all Historian examples is now 1.

Added to errata 1.03.4

Jim Luth

2016-11-22 16:18

administrator   ~0007355

Agreed to changes in Telecon.

Issue History

Date Modified Username Field Change
2016-11-15 21:10 Rod Stein New Issue
2016-11-15 21:10 Rod Stein Status new => assigned
2016-11-15 21:10 Rod Stein Assigned To => Rod Stein
2016-11-15 21:19 Rod Stein Note Added: 0007320
2016-11-15 21:19 Rod Stein Status assigned => resolved
2016-11-15 21:19 Rod Stein Fixed in Version => 1.04
2016-11-15 21:19 Rod Stein Resolution open => fixed
2016-11-22 16:12 Jim Luth Issue cloned: 0003611
2016-11-22 16:12 Jim Luth Relationship added related to 0003611
2016-11-22 16:18 Jim Luth Note Added: 0007355
2016-11-22 16:18 Jim Luth Status resolved => closed