View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0003983 | Compliance Test Tool (CTT) Unified Architecture | 1 - Script Issue | public | 2017-10-10 12:56 | 2019-05-27 14:41 |
Reporter | Hannes Mezger | Assigned To | Alexander Allmendinger | ||
Priority | normal | Severity | minor | Reproducibility | always |
Status | closed | Resolution | fixed | ||
Target Version | 1.03 | Fixed in Version | 1.03.340.368 | ||
Summary | 0003983: Base Info Server Capabilities | ||||
Description | If the server's limits are above certain values (e.g. MaxStringLength above 10000), the tests are not being executed at all, there should be some big big big warning that limits above value X are not being tested at all. Otherwise one wouldn't notify that the tests are skipped. | ||||
Tags | No tags attached. | ||||
Files Affected | |||||
|
Change the behavior for not skipping but using a high value. |
|
Scripts are now using the MAX_ALLOWED_SIZE for the OperationLimit testing. |
|
reviewed in extra Compliance call 2019-05-27 |
Date Modified | Username | Field | Change |
---|---|---|---|
2017-10-10 12:56 | Hannes Mezger | New Issue | |
2017-10-10 12:56 | Hannes Mezger | Status | new => assigned |
2017-10-10 12:56 | Hannes Mezger | Assigned To | => Alexander Allmendinger |
2017-10-26 16:08 | Alexander Allmendinger | Note Added: 0008614 | |
2017-10-26 16:08 | Alexander Allmendinger | Target Version | => 1.03 |
2017-10-29 21:15 | Alexander Allmendinger | Note Added: 0008616 | |
2017-10-29 21:15 | Alexander Allmendinger | Status | assigned => resolved |
2017-10-29 21:15 | Alexander Allmendinger | Fixed in Version | => 1.03.340.368 |
2017-10-29 21:15 | Alexander Allmendinger | Resolution | open => fixed |
2019-01-28 14:10 | Paul Hunkar | Category | Script Issue => 1 - Script Issue |
2019-05-27 14:41 | Paul Hunkar | Status | resolved => closed |
2019-05-27 14:41 | Paul Hunkar | Note Added: 0010273 |