Summary0004428: Security User X509 Initialize fails depending of the order the Endpoints are provided
Description

In the x509policyExists() the script does iterate through all available Endpoints and is setting the first endpoint supporting X509 as Endpoint to test. But then the test case is creating a connection with default parameters if this endpoint does provide the X509 UserIdentityToken as well. This leads to the fact that different algorithms are being used.

Additional Information

x509policyExists() needs to test the standard connection parameter first for supporting the X509 UserIdentityToken and just if not continuing with the others.

TagsNo tags attached.
Files Affected

Activities

Alexander Allmendinger

2018-10-30 18:17

developer   ~0009504

Followed suggestion

Paul Hunkar

2019-08-07 11:35

administrator   ~0010695

reviewed in CMP call 8/1/2019

Issue History

Date Modified Username Field Change
2018-10-30 18:15 Alexander Allmendinger New Issue
2018-10-30 18:15 Alexander Allmendinger Status new => assigned
2018-10-30 18:15 Alexander Allmendinger Assigned To => Alexander Allmendinger
2018-10-30 18:17 Alexander Allmendinger Note Added: 0009504
2018-10-30 18:17 Alexander Allmendinger Status assigned => resolved
2018-10-30 18:17 Alexander Allmendinger Fixed in Version => 1.03.341.381
2018-10-30 18:17 Alexander Allmendinger Resolution open => fixed
2019-01-28 14:10 Paul Hunkar Category Script Issue => 1 - Script Issue
2019-08-07 11:35 Paul Hunkar Status resolved => closed
2019-08-07 11:35 Paul Hunkar Note Added: 0010695