View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0004750 | Compliance Test Tool (CTT) Unified Architecture | 2 - CTT Binary | public | 2019-05-02 14:36 | 2019-07-25 13:21 |
| Reporter | Alexander Allmendinger | Assigned To | Alexander Allmendinger | ||
| Priority | normal | Severity | crash | Reproducibility | always |
| Status | closed | Resolution | fixed | ||
| Product Version | 1.03.341.389 | ||||
| Target Version | 1.03 | Fixed in Version | 1.03.341.390 | ||
| Summary | 0004750: CTT crashes when making use of the FindObjectsOfTypeService | ||||
| Description | When the CTT is building the offline AddressSpace for an incompliant server the CTT is crashing with an access violation. | ||||
| Steps To Reproduce | Loading an address space in a server with references to non-existing UaNodes e.g. in the HasModellingRule or HasTypeDefinition | ||||
| Tags | No tags attached. | ||||
| Files Affected | |||||
|
|
There was a missing check in case the read of a NodeId failed due to AccessRight restrictions or other cases. Also added trace output in case a read on a reference fails in order to provide more trace information to the user of the CTT. |
|
|
Reviewed in CMP call |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2019-05-02 14:36 | Alexander Allmendinger | New Issue | |
| 2019-05-02 15:08 | Alexander Allmendinger | Steps to Reproduce Updated | |
| 2019-05-02 15:11 | Paul Hunkar | Assigned To | => Alexander Allmendinger |
| 2019-05-02 15:11 | Paul Hunkar | Status | new => assigned |
| 2019-07-24 09:53 | Alexander Allmendinger | Status | assigned => resolved |
| 2019-07-24 09:53 | Alexander Allmendinger | Resolution | open => fixed |
| 2019-07-24 09:53 | Alexander Allmendinger | Fixed in Version | => 1.03.341.390 |
| 2019-07-24 09:53 | Alexander Allmendinger | Note Added: 0010569 | |
| 2019-07-25 13:21 | Paul Hunkar | Status | resolved => closed |
| 2019-07-25 13:21 | Paul Hunkar | Note Added: 0010582 |