View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0004783 | Compliance Test Tool (CTT) Unified Architecture | 1 - Script Issue | public | 2019-06-13 12:04 | 2020-04-24 17:22 |
| Reporter | Frank Fischer | Assigned To | Alexander Allmendinger | ||
| Priority | high | Severity | major | Reproducibility | always |
| Status | closed | Resolution | fixed | ||
| Product Version | 1.03.341.389 | ||||
| Fixed in Version | 1.03.341.390 | ||||
| Summary | 0004783: Base Information/Base Info Diagnostics/initialize.js | ||||
| Description | In line 43 the script reads the attribute UserWriteMask of i=2294 and expects the statuscode good, however according to Part 3, "Table 17 – Overview of Attributes" the UserWriteMask is optional for all nodeclasses and the server may as well return BadAttributeIdInvalid which should be accepted. | ||||
| Tags | No tags attached. | ||||
| Files Affected | |||||
|
|
Removed the Read of the attributes as this is not necessary in the initialize. Fix was already checked in on 4th of September 2019 |
|
|
review in CMP call |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2019-06-13 12:04 | Frank Fischer | New Issue | |
| 2019-06-13 14:25 | Alexander Allmendinger | Assigned To | => Alexander Allmendinger |
| 2019-06-13 14:25 | Alexander Allmendinger | Status | new => assigned |
| 2019-11-03 17:37 | Alexander Allmendinger | Status | assigned => resolved |
| 2019-11-03 17:37 | Alexander Allmendinger | Resolution | open => fixed |
| 2019-11-03 17:37 | Alexander Allmendinger | Fixed in Version | => 1.03.341.390 |
| 2019-11-03 17:37 | Alexander Allmendinger | Note Added: 0011186 | |
| 2020-04-24 17:22 | Paul Hunkar | Status | resolved => closed |
| 2020-04-24 17:22 | Paul Hunkar | Note Added: 0011990 |