View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0004786 | Compliance Test Tool (CTT) Unified Architecture | 1 - Script Issue | public | 2019-06-18 13:42 | 2020-07-03 16:46 |
| Reporter | Frank Fischer | Assigned To | Sebastian Allmendinger | ||
| Priority | high | Severity | major | Reproducibility | always |
| Status | closed | Resolution | fixed | ||
| Product Version | 1.03.341.389 | ||||
| Fixed in Version | 1.03.341.390 | ||||
| Summary | 0004786: Base Information/Base Info Type System/DataTypesValidation.js | ||||
| Description | The scripts seems to ignore continuation points during browse, for the node i=7617 (OpcUa_BinarySchema) the CTT claims it has not TypeDefinition reference, but it appears when browsing with UAExpert. After increasing the max_references_per_node limit of the server from 100 to 1000 the test succeeds. | ||||
| Tags | No tags attached. | ||||
| Files Affected | |||||
|
|
The test script has been updated to continue browsing until no continuation point is available. |
|
|
also addition clean performed on this updated reviewed in CMP call |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2019-06-18 13:42 | Frank Fischer | New Issue | |
| 2019-06-26 16:43 | Paul Hunkar | Assigned To | => Alexander Allmendinger |
| 2019-06-26 16:43 | Paul Hunkar | Status | new => assigned |
| 2019-11-21 07:46 | Sebastian Allmendinger | Assigned To | Alexander Allmendinger => Sebastian Allmendinger |
| 2019-11-21 08:27 | Sebastian Allmendinger | Status | assigned => resolved |
| 2019-11-21 08:27 | Sebastian Allmendinger | Resolution | open => fixed |
| 2019-11-21 08:27 | Sebastian Allmendinger | Fixed in Version | => 1.03.341.390 |
| 2019-11-21 08:27 | Sebastian Allmendinger | Note Added: 0011255 | |
| 2020-07-03 16:46 | Paul Hunkar | Status | resolved => closed |
| 2020-07-03 16:46 | Paul Hunkar | Note Added: 0012546 |