Summary0005438: CTT is not honoring the OperationLimit MaxNodesPerMethodCall
Description

If a server is providing the MaxNodesPerMethodCall node the CTT shouldn't call more methods in a single call than supported by the server and split the request in multiple calls (just like it is already implemented for the Read/Write/... services).

TagsNo tags attached.
Files Affected

Activities

Sebastian Allmendinger

2020-02-08 10:15

developer   ~0011565

If the server is providing the OperationLimit MaxNodesPerMethodCall the CTT is now honoring this value. Because some test scripts don't want to split the call request this can be forced by setting the parameter ProhibitSplitting to true.

Paul Hunkar

2020-04-30 14:30

administrator   ~0012016

reviewed ion CMP call

Issue History

Date Modified Username Field Change
2020-02-05 09:23 Sebastian Allmendinger New Issue
2020-02-08 05:19 Paul Hunkar Assigned To => Alexander Allmendinger
2020-02-08 05:19 Paul Hunkar Status new => assigned
2020-02-08 10:15 Sebastian Allmendinger Assigned To Alexander Allmendinger => Sebastian Allmendinger
2020-02-08 10:15 Sebastian Allmendinger Status assigned => resolved
2020-02-08 10:15 Sebastian Allmendinger Resolution open => fixed
2020-02-08 10:15 Sebastian Allmendinger Fixed in Version => 1.03.341.394
2020-02-08 10:15 Sebastian Allmendinger Note Added: 0011565
2020-04-30 14:30 Paul Hunkar Status resolved => closed
2020-04-30 14:30 Paul Hunkar Note Added: 0012016