0005663 | Compliance Test Tool (CTT) Unified Architecture | 1 - Script Issue | public | 2020-05-25 05:59 | 2020-06-03 17:03 |
Reporter | Lauri Saurus | Assigned To | Alexander Allmendinger | ||
Priority | normal | Severity | major | Reproducibility | always |
Status | closed | Resolution | fixed | ||
Fixed in Version | 1.03.341.396 | ||||
Summary | 0005663: Test Data Access -> Data Access AnalogItemType-> 010.js fails with some AnalogItems defined in settings | ||||
Description | There is a problem in the test that it uses the UaNodeId.GuessType method to deduce DataType from the NodeSetting name. It does not seem to handle NodeIdWithEngineeringUnits and NodeIdWithInstrumentRange settings. It returns undefined for those nodes. Settings are located under Server Test -> NodeIds -> DA Profile -> AnalogType. Because of undefined return value the verification will fail. Should those two AnalogItems be skipped in the verification? | ||||
Steps To Reproduce | Set setting NodeIdWithEngineeringUnits and NodeIdWithInstrumentRange to valid nodes and run the test. | ||||
Tags | No tags attached. | ||||
Files Affected | |||||
|
There are two issues in this script:
|
|
reviewed in CMP Call |
Date Modified | Username | Field | Change |
---|---|---|---|
2020-05-25 05:59 | Lauri Saurus | New Issue | |
2020-05-27 17:28 | Paul Hunkar | Assigned To | => Alexander Allmendinger |
2020-05-27 17:28 | Paul Hunkar | Status | new => assigned |
2020-06-02 14:57 | Alexander Allmendinger | Status | assigned => resolved |
2020-06-02 14:57 | Alexander Allmendinger | Resolution | open => fixed |
2020-06-02 14:57 | Alexander Allmendinger | Fixed in Version | => 1.03.341.396 |
2020-06-02 14:57 | Alexander Allmendinger | Note Added: 0012155 | |
2020-06-03 17:03 | Paul Hunkar | Status | resolved => closed |
2020-06-03 17:03 | Paul Hunkar | Note Added: 0012168 |