View Issue Details

IDProjectCategoryView StatusLast Update
0005853Compliance Test Tool (CTT) Unified Architecture1 - Script Issuepublic2021-07-02 14:38
ReporterKarl Mayr Assigned ToSebastian Allmendinger  
PrioritynormalSeverityminorReproducibilityalways
Status closedResolutionfixed 
Product Version1.04.09.396 
Fixed in Version1.03.341.399 
Summary0005853: Monitored Item Services / Monitor MinQueueSize_02 / 009.js error message incorrect
Description

The received DateTime value does not match the expected/written value and therefore an error occurs.
The solution for IEC data type DATE_AND_TIME is vendor specific and therefore it is likely a problem of the CTT if a wrong error message is issued.
See description in the attached file.

TagsNo tags attached.
Attached Files
Files Affected

Relationships

duplicate of 0005642 closedSebastian Allmendinger Monitored Item Services/Monitor MinQueueSize_02/009 

Activities

Paul Hunkar

2020-08-13 14:22

administrator   ~0012678

for this test the the overflow bit must be set in the last value in the queue (not the first value) since that value is sowing that items were missed. There might be a time stamp issue as well.

Sebastian Allmendinger

2021-05-28 13:09

developer   ~0014437

The CTT already allows to truncate a DateTime value to a resolution of 1 second (see linked MantisId for more information).
An updated version of this test script has now been prepared to get rid of the misleading/wrong error message.

Paul Hunkar

2021-07-02 14:38

administrator   ~0014607

reviewed in CMP call , agreed to change and closed

Issue History

Date Modified Username Field Change
2020-07-31 08:09 Karl Mayr New Issue
2020-07-31 08:09 Karl Mayr File Added: Monitored Item Services.pdf
2020-08-13 14:22 Paul Hunkar Note Added: 0012678
2020-08-13 14:22 Paul Hunkar Assigned To => Alexander Allmendinger
2020-08-13 14:22 Paul Hunkar Status new => assigned
2020-08-24 08:14 Sebastian Allmendinger Relationship added duplicate of 0005642
2020-08-24 08:14 Sebastian Allmendinger Assigned To Alexander Allmendinger => Sebastian Allmendinger
2021-05-28 13:09 Sebastian Allmendinger Status assigned => resolved
2021-05-28 13:09 Sebastian Allmendinger Resolution open => fixed
2021-05-28 13:09 Sebastian Allmendinger Fixed in Version => 1.03.341.399
2021-05-28 13:09 Sebastian Allmendinger Note Added: 0014437
2021-07-02 14:38 Paul Hunkar Status resolved => closed
2021-07-02 14:38 Paul Hunkar Note Added: 0014607