Summary0007333: Missing relation of types to conformance units and profiles
Description

At the moment it is not possible to identify the relation of a type or of instances to a conformance unit and to profiles. This is a growing problem since the OPC UA namespace is constantly extended and there is no way for tooling to reduce the exposed types if only a subset of the OPC UA features is implemented.

OPC UA Part 6 defines a Category field for a Node in the UANodeset. The Category takes a String [ ]. There is currently no information defined that goes into this category. It can be used to provide a list of conformance units.

Each type table needs to add the conformance unit(s) it is related to to allow tooling to select the necessary types based on the profile selection.

The conformance unit goes into the Category of the UANodeset for processing in tooling.

Additional Information

As agreed in the OPC UA meeting on July 14, 2020, each type table must be extended with a list of conformance units that require the type.

Add rows with one column to the end of the table.
The first row contains the heading "Conformance Units" in bold.
The second and following rows contain the name of the conformance units the type is required for.
This is typically one conformance unit.

Example can be found in the following document:
OPC 10000-8 - UA Specification Part 8 - DataAccess Draft 1.05.06.ExtensionCategory2.docx
posted in:
https://opcfoundation.sharepoint.com/UA/Work/Forms/AllItems.aspx?RootFolder=%2FUA%2Fwork%2FMeetings%2F2020%2F2020%2D07%2D14%20Weekly%20Telecon&FolderCTID=0x012000FDF01D76A1A64246B261F99AF1ACA00A&View=%7B10076F95%2D9CBF%2D4395%2D8545%2D378F95701D6A%7D

TagsNo tags attached.
Attached Files
Commit Version
Fix Due Date

Relationships

related to 0006982 closedWolfgang Mahnke 10000-022: Base Network Model Missing relation of types to conformance units and profiles 

Activities

Wolfgang Mahnke

2021-09-28 15:27

developer   ~0015041

Fixed in 1.05.1

Greg Majcher

2021-09-28 15:27

reporter   ~0015042

Conformance units attached

Karl Deiretsbacher

2021-11-07 11:24

developer   ~0015279

Added missing CUs to the 1.05 database.

Jim Luth

2022-03-07 16:49

administrator   ~0016226

Agreed to close in virtual F2F.

Issue History

Date Modified Username Field Change
2021-09-28 15:27 Jim Luth New Issue
2021-09-28 15:27 Jim Luth Status new => assigned
2021-09-28 15:27 Jim Luth Assigned To => Wolfgang Mahnke
2021-09-28 15:27 Jim Luth Issue generated from: 0006982
2021-09-28 15:27 Jim Luth Note Added: 0015041
2021-09-28 15:27 Jim Luth Note Added: 0015042
2021-09-28 15:27 Jim Luth Relationship added related to 0006982
2021-09-28 15:28 Jim Luth Project 10000-022: Base Network Model => 10000-007: Profiles
2021-09-28 15:28 Jim Luth Assigned To Wolfgang Mahnke => Karl Deiretsbacher
2021-11-07 11:24 Karl Deiretsbacher Status assigned => resolved
2021-11-07 11:24 Karl Deiretsbacher Resolution open => fixed
2021-11-07 11:24 Karl Deiretsbacher Note Added: 0015279
2022-03-07 16:49 Jim Luth Status resolved => closed
2022-03-07 16:49 Jim Luth Fixed in Version => 1.05
2022-03-07 16:49 Jim Luth Note Added: 0016226