View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0007892 | 10000-006: Mappings | Spec | public | 2022-03-25 13:00 | 2023-01-03 17:13 |
Reporter | Kevin Herron (Inductive Automation) | Assigned To | Randy Armstrong | ||
Priority | normal | Severity | minor | Reproducibility | always |
Status | closed | Resolution | fixed | ||
Product Version | 1.04 | ||||
Fixed in Version | 1.05.03 RC1 | ||||
Summary | 0007892: OPC UA JSON Encoding DataValue Picosecond Field Names | ||||
Description | Part 6 describes the name of the This is inconsistent with the names used by the other encodings as well as the .NET Standard implementation. They should be | ||||
Tags | No tags attached. | ||||
Commit Version | |||||
Fix Due Date | |||||
|
Replaced PicoSeconds with Picoseconds since that is consistent with the generated code. |
|
Agreed to changes in telecon. |
Date Modified | Username | Field | Change |
---|---|---|---|
2022-03-25 13:00 | Kevin Herron (Inductive Automation) | New Issue | |
2022-03-25 13:14 | Kevin Herron (Inductive Automation) | Reproducibility | have not tried => always |
2022-03-25 13:14 | Kevin Herron (Inductive Automation) | Product Version | => 1.04 |
2022-07-05 17:06 | Jim Luth | Assigned To | => Randy Armstrong |
2022-07-05 17:06 | Jim Luth | Status | new => assigned |
2022-12-29 17:10 | Randy Armstrong | Status | assigned => resolved |
2022-12-29 17:10 | Randy Armstrong | Resolution | open => fixed |
2022-12-29 17:10 | Randy Armstrong | Fixed in Version | => 1.05.03 RC1 |
2022-12-29 17:10 | Randy Armstrong | Note Added: 0018375 | |
2023-01-03 17:13 | Jim Luth | Status | resolved => closed |
2023-01-03 17:13 | Jim Luth | Note Added: 0018395 |