View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0008026 | CTT UA Scripts | 1 - Script Issue | public | 2022-06-03 09:15 | 2022-09-09 16:15 |
Reporter | Yannik Klaass | Assigned To | Yannik Klaass | ||
Priority | normal | Severity | minor | Reproducibility | always |
Status | closed | Resolution | fixed | ||
Fixed in Version | 1.03.501 | ||||
Summary | 0008026: Attribute Write Values: Some scripts skip incorrectly | ||||
Description | In Attribute Write Values, several scripts (001, 003, 005, 006 and Err-005) return unexpected errors ('originalScalarValues[0]' [undefined] is not an object) or BadNothingToDo if readonly or no Scalar nodes are configured. Also if no Scalar and Array nodes are configured, the skipping of the CU in initialize -> line 39 does not trigger. | ||||
Tags | No tags attached. | ||||
Files Affected | |||||
related to | 0007047 | closed | Yannik Klaass | Failing write tests on a read only OPC UA Server |
|
Issues have been resolved by getting only writable items with fromSettingsExt where needed and fixing the skips |
|
this affected scripts 001, 003,005,006,007,009,010,011,012,013,,017,018 |
Date Modified | Username | Field | Change |
---|---|---|---|
2022-06-03 09:15 | Yannik Klaass | New Issue | |
2022-08-04 15:08 | Paul Hunkar | Assigned To | => Yannik Klaass |
2022-08-04 15:08 | Paul Hunkar | Status | new => assigned |
2022-08-15 12:43 | Yannik Klaass | Status | assigned => resolved |
2022-08-15 12:43 | Yannik Klaass | Resolution | open => fixed |
2022-08-15 12:43 | Yannik Klaass | Note Added: 0017320 | |
2022-08-25 03:09 | Paul Hunkar | Project | Compliance Test Tool (CTT) Unified Architecture => CTT UA Scripts |
2022-09-07 12:18 | Yannik Klaass | Relationship added | related to 0007047 |
2022-09-09 16:15 | Paul Hunkar | Note Added: 0017601 | |
2022-09-09 16:15 | Paul Hunkar | Status | resolved => closed |
2022-09-09 16:15 | Paul Hunkar | Fixed in Version | => 1.03.501 |