Description

UAFX AutomationComponent ConnectionEstablishment ReserveCommunicationIds should not be Optional in the UAFX AutomationComponent Facet. There are situations where Reserve is needed (e.g. multiple ACs with multiple connections).

TagsNo tags attached.

Activities

Bob Lattimer

2022-09-05 16:54

manager   ~0017524

From Georg:
If we set this to True a CM would never be able to use the commands, since we have no indication whether an AC supports Reserve and Enable. Note: The command EstablishControl and ReassignControl must be supported if the AC has ControlGroups (otherwise, they would not be usable with a connection). The command SetConfigurationData must be supported if the AC has ConfigurationData (otherwise, they would not be usable with a connection).

Thus: Reserve and Enable MUST be set to False

Greg Majcher

2022-09-21 13:10

manager   ~0017748

The AWG agreed that this CU should be required. It was changed to required in Part 84 and in the Profile Reporting Tool.

Greg Majcher

2022-09-21 21:40

manager   ~0017778

The changes were reviewed during the 9/21 AWG call.

Issue History

Date Modified Username Field Change
2022-09-05 16:53 Bob Lattimer New Issue
2022-09-05 16:54 Bob Lattimer Note Added: 0017524
2022-09-21 13:08 Greg Majcher Assigned To => Bob Lattimer
2022-09-21 13:08 Greg Majcher Status new => assigned
2022-09-21 13:10 Greg Majcher Status assigned => resolved
2022-09-21 13:10 Greg Majcher Resolution open => fixed
2022-09-21 13:10 Greg Majcher Note Added: 0017748
2022-09-21 21:40 Greg Majcher Status resolved => closed