View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0009346 | Compliance Test Tool (CTT) Unified Architecture | 1 - Script Issue | public | 2024-01-10 15:10 | 2024-11-22 09:34 |
Reporter | Frank Fischer | Assigned To | Yannik Klaass | ||
Priority | high | Severity | major | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Platform | PC | OS | Linux | OS Version | Debian 12 |
Product Version | 1.04.09.401 | ||||
Summary | 0009346: CTT does not know 0x80f00000 (Bad_NoValue) | ||||
Description | As of the UA Specification 1.05.03 it is required to use the new statuscode Bad_NoValue for Variables which have no value (see issue 0008757). This effects a lot of namespace 0 nodes, e.g. most of the Variables below BaseObjectType or Variables below the Server Object which are not used by the server. So 'Base Information/Base Info Core Structure/001' fails with errors like this: Furthermore every beforeTest, afterTest and initialize fails when reading the server capabilities with such errors: There may be more errors related to this issue, but literally every testcase is failing, so the CTT is completely unusable. | ||||
Steps To Reproduce | Start a server that correctly returns Bad_NoValue | ||||
Additional Information | CTT Version is actually V1.04.11-01.00.506-x86_64 but this isn't available for selection in the box | ||||
Tags | No tags attached. | ||||
Files Affected | |||||
related to | 0009785 | closed | Yannik Klaass | CTT UA Binary | Update types, statuscodes and identifiers to 1.05.03 specification |
|
fix adding Bad_NoValue to CTT, after which we will clone to look at other aspects of the issue |
|
StatusCode Bad_NoValue is added along with the update to the 1.05.03 specification (see related issue 0009785) |
Date Modified | Username | Field | Change |
---|---|---|---|
2024-01-10 15:10 | Frank Fischer | New Issue | |
2024-01-12 17:04 | Paul Hunkar | Note Added: 0020630 | |
2024-01-12 17:04 | Paul Hunkar | Assigned To | => Alexander Allmendinger |
2024-01-12 17:04 | Paul Hunkar | Status | new => assigned |
2024-01-18 11:17 | Alexander Allmendinger | Assigned To | Alexander Allmendinger => Yannik Klaass |
2024-08-27 12:36 | Yannik Klaass | Relationship added | related to 0009785 |
2024-11-22 09:34 | Yannik Klaass | Status | assigned => resolved |
2024-11-22 09:34 | Yannik Klaass | Resolution | open => fixed |
2024-11-22 09:34 | Yannik Klaass | Note Added: 0022095 |