0009486Part 81: UAFX Connecting Devices and Information ModelSpecpublic2024-09-17 18:35
ReporterSuad Morgan Assigned ToPaul Hunkar  
PrioritynormalSeverityfeatureReproducibilityalways
Status assignedResolutionopen 
Product Version1.00.02 
Target Version1.00.03 
Summary0009486: OPC UA FX Part 81 Does Not Convey Capabilities of Supported Data Types for Automation Component
Description

When exchanging descriptors, engineering tools are unable to predict the supported data types of the automation component due to the absence of conveying capabilities in descriptor or Part 81."

Steps To Reproduce

Engineer A exports a descriptor of Automation Component (AC) that has Functional Extension (FE) with output variables of type Int64.
Engineer B imports the descriptor, but AC B can only support variables of type Int32.
This forces the two engineers to communicate about the issue and how to fix. The specification is silent about how to include this capability or how to solve it.

TagsNo tags attached.

Activities

Emanuel Kolb

2024-09-17 18:34

developer   ~0021733

The capabilities fur supporting a built-in datatype should be present in the information model in order to be available in a descriptor. Therefore this is a task for the base facet team to define the necessary UA variables.

Issue History

Date Modified Username Field Change
2024-03-21 07:26 Suad Morgan New Issue
2024-09-12 12:56 Emanuel Kolb Target Version => 1.00.03
2024-09-17 18:34 Emanuel Kolb Note Added: 0021733
2024-09-17 18:35 Jim Luth Assigned To => Paul Hunkar
2024-09-17 18:35 Jim Luth Status new => assigned