View Issue Details

IDProjectCategoryView StatusLast Update
0009796Part 81: UAFX Connecting Devices and Information ModelSpecpublic2024-10-04 04:51
ReporterBob Lattimer Assigned ToPaul Hunkar  
PriorityhighSeverityminorReproducibilityhave not tried
Status resolvedResolutionfixed 
Product Version1.00.02 
Target Version1.00.03Fixed in Version1.00.03 
Summary0009796: Requiring CCSs be exposed in a CM
Description

It was agreed in a BFWG meeting that a CCS will be exposed for every Connection this CM establishes. The requirement should be made mandatory ("may" now) in the sentence in Part 81 Clause 6.8.1, which makes CCSs optional, with additional text explaining the conditions when a CCS must be exposed. For example, "A CCS shall be exposed for every Connection this CM establishes." The CCSs the CM uses to make a Connection, i.e., provided by an external Client, will already be exposed and need to be after those Connections are established.

TagsNo tags attached.

Relationships

related to 0009798 new Specify what's mandatory in a CCS exposed by a CM 

Activities

Paul Hunkar

2024-10-04 04:51

manager   ~0021825

Updated text to change a may exposes CCS to a shall expose CCS

Issue History

Date Modified Username Field Change
2024-08-23 03:05 Bob Lattimer New Issue
2024-08-23 12:17 Paul Hunkar Relationship added related to 0009798
2024-10-04 04:48 Paul Hunkar Assigned To => Paul Hunkar
2024-10-04 04:48 Paul Hunkar Status new => assigned
2024-10-04 04:51 Paul Hunkar Status assigned => resolved
2024-10-04 04:51 Paul Hunkar Resolution open => fixed
2024-10-04 04:51 Paul Hunkar Fixed in Version => 1.00.03
2024-10-04 04:51 Paul Hunkar Note Added: 0021825