View Issue Details

IDProjectCategoryView StatusLast Update
000982510000-012: DiscoverySpecpublic2024-10-07 05:24
ReporterMatthias Damm Assigned ToRandy Armstrong  
PrioritynormalSeveritymajorReproducibilityhave not tried
Status resolvedResolutionfixed 
Product Version1.05.04 RC1 
Target Version1.05.04 
Summary0009825: Invalid ConfigurationFileType Open mode option specified
Description

The Open Method mode Read + Write + EraseExisting (0x07) does not work.

This is different than PubSub and does not work since Read and EraseExisting cannot be combined.

PubSub defines “Read + Write (0x03)” instead. This is prooven, implemented and works.

TagsNo tags attached.
Commit Version
Fix Due Date

Activities

Randy Armstrong

2024-10-07 05:24

administrator   ~0021840

Fixed

Issue History

Date Modified Username Field Change
2024-09-10 09:22 Matthias Damm New Issue
2024-10-07 05:24 Randy Armstrong Assigned To => Randy Armstrong
2024-10-07 05:24 Randy Armstrong Status new => resolved
2024-10-07 05:24 Randy Armstrong Resolution open => fixed
2024-10-07 05:24 Randy Armstrong Note Added: 0021840