| | | 0009131 | 2 | |
| major | | 2023-09-04 | MonitoredItem.fromSettings() should not be called with with client handles different from MonitoredItem.GetNextClientHandIe() 2 |
| | | 0008610 | 2 | |
V1.01 | minor | | 2023-09-01 | Restructuring of ConformanceUnits |
| | | 0009126 | 1 | |
| tweak | feedback | 2023-09-01 | Usage of EnumValues instead of EnumString |
| | | 0008623 | 2 | 1 |
| minor | | 2023-09-01 | Update nodeset file for Companion Specification V1.01 |
| | | 0009078 | 3 | 2 |
V1.01 | minor | | 2023-09-01 | Remove MasterConfigurationDisabled read-only condition for ethernet configuration |
| | | 0008272 | 4 | 1 |
| minor | | 2023-08-31 | Unclear whether ActiveState variable from AlarmConditionType is Read/Write or Read-Only |
| | | 0009114 | | |
| minor | new | 2023-08-18 | Backward link from conformance units to specification parts |
| | | 0008676 | 5 | |
| feature | acknowledged | 2023-08-14 | Integer-based alternative for AnalogUnitRangeType needed by e.g. UA FX Motion WG |
| | | 0009071 | | |
| minor | acknowledged | 2023-08-14 | Add Support for TSN |
| | | 0009103 | | |
| minor | | 2023-08-14 | Seemingly odd default values for EngineeringUnits in some types in the NodeSet |
| | | 0009101 | | 1 |
| minor | | 2023-08-14 | Name of Schema Nodes in XML different from other specifications |
| | | 0009099 | | |
| minor | | 2023-08-14 | Multiple Nodes of AnalogItemType have EngineeringUnits set to mandatory in the NodeSet File, not indicated in spec document |
| | | 0009097 | | |
| minor | | 2023-08-14 | Additional mandatory components defined in NodeSet XML for CncSpindleType instance in CncSpindleListType |
| | | 0009095 | 1 | 1 |
| minor | new | 2023-08-11 | Example Instance in Spec Namespace in XML |
| | | 0009094 | | |
| minor | new | 2023-08-11 | Unreferenced nodes in NodeSet |
| | | 0008621 | | 1 |
| feature | acknowledged | 2023-08-10 | Expand alarm model to include Alerts and notifications |
| | | 0008682 | 3 | |
| minor | feedback | 2023-08-10 | Make sure OPC UA references are accurate in WoT Thing Descriptions |
| | | 0009089 | | |
| minor | new | 2023-08-09 | A better example is needed to demonstrate descriptor use in modular IO systems |
| | | 0009084 | 1 | |
| minor | | 2023-08-08 | Add CU for optional PubSubCapabilities Object |
| | | 0005272 | 2 | |
| minor | | 2023-08-08 | Provide additional aggregate design guidance |
| | | 0003894 | 2 | 1 |
| feature | | 2023-08-08 | Aggregated Objects vs. Folders (Standard too flexible) |
| | | 0005048 | 3 | |
| text | | 2023-08-08 | Nodeset2.xml link in specification points to outdated file |
| | | 0007373 | 5 | |
V1.01 | minor | | 2023-08-03 | 1:PDDescriptor variable has wrong default value type |
| | | 0008954 | 2 | |
| minor | | 2023-08-03 | Redundant mandatory Property "IOLinkEventCode" (6338) under "IOLinkPortEventType" (1005) in NodeSet2 XML |
| | | 0008958 | 2 | |
| minor | acknowledged | 2023-08-01 | An idea how to compress the GetEndpointsResponse |
| | | 0008767 | 4 | |
| feature | acknowledged | 2023-08-01 | Need support for RolePermissions in NodeSet |
| | | 0009037 | 3 | |
| minor | | 2023-07-31 | CTT needs a user with admin permissions to check diagnostic nodes |
| | | 0009064 | 1 | |
| minor | | 2023-07-31 | CTT needs a user with admin permissions to check diagnostic nodes |
| | | 0007360 | 8 | |
| major | | 2023-07-29 | Creating PKI folder for Linux (.AppImage) is not possible on the fly for the CI usage (Jenkins) |
| | | 0008928 | | |
| minor | acknowledged | 2023-07-25 | Clarification on InstanceDeclarations |
| | | 0007885 | 1 | |
| minor | acknowledged | 2023-07-25 | Need a Discussion of How the Role Model is applied to MQTT Brokers |
| | | 0009011 | | |
| minor | acknowledged | 2023-07-25 | Unclear MQTT authentication |
| | | 0009020 | | |
| minor | acknowledged | 2023-07-25 | Unclear child state changes for parent PreOperational |
| | | 0009031 | 2 | |
| minor | acknowledged | 2023-07-25 | RawData encoding with reversible JSON |
| | | 0009044 | 1 | |
| minor | acknowledged | 2023-07-25 | Clarify use of the serverUri field in the CreateSession request |
| | | 0009054 | | |
| feature | | 2023-07-24 | Possibility to prevent onboarding of a device by the manufacturer. |
| | | 0008882 | | |
| major | new | 2023-07-17 | NodeSet missing ParentNodeIds |
| | | 0009038 | | |
| minor | | 2023-07-05 | PubSub capablities do not have indication about minimum supported PublishingInterval |
| | | 0007556 | 1 | |
1.04 | minor | | 2023-06-26 | Documentation for the CTT could be improved |
| | | 0007739 | | |
| feature | | 2023-06-22 | IANA registered IPv6 multicast address for discovery |
| | | 0007738 | | |
| minor | | 2023-06-22 | Add overview figure for UPD transport protocol mapping |
| | | 0008390 | | |
| minor | | 2023-06-22 | NetworkInterface handling for UDP |
| | | 0005508 | 5 | |
| minor | acknowledged | 2023-06-22 | AccessLevel (writer capability) undefined for TargetVariables |
| | | 0003731 | 2 | |
| feature | | 2023-06-21 | PubSub object state based on condition |
| | | 0008002 | 3 | |
| minor | | 2023-06-21 | SecurityGroup needs an Identity that can be used to determine access to Variables |
| | | 0006603 | 1 | |
| minor | | 2023-06-21 | Figure 21 - Establishing a SecureChannel |
| | | 0009021 | | |
| minor | | 2023-06-21 | Many detailed clarifications missing of Like |
| | | 0006651 | | |
| minor | | 2023-06-21 | several missing or wrong conversion rules of FilterOperator |
| | | 0008267 | | |
| minor | | 2023-06-20 | Need description of using centrally managed users, passwords and Roles with Servers from multiple vendors |
| | | 0008677 | | |
| minor | | 2023-06-20 | How to restrict applications for a role configured through the same role |