Part 81: UAFX Connecting Devices and Information Model - Change Log
Released 2023-09-20
- 0008997: [Spec] Indicate support of one-to-many unicast and multicast communications (Georg Biehler)
- 0009269: [Spec] Mandatory variable AggregatedHealth is aggregating optional variables DeviceHealth and OperationalHealth. (Bob Lattimer)
- 0009187: [Spec] updated example to include the new interface for connectors (Paul Hunkar)
- 0009333: [Spec] FunctionalEntityNode is not a child of the AutomationComponent on which the EsatblishConnections was called. (Paul Hunkar)
- 0009334: [Spec] PubSubConnectionEndpointParameterDataType.Mode is not consistent with InputVariableIds (or Output). (Paul Hunkar)
- 0009223: [Spec] Allow creation of ConnectionEndpoints that reference input variables referenced by another enabled Connection (Paul Hunkar)
- 0009335: [Spec] EnableCommunication command is called on an endpoint which is still in an Initial state. (Paul Hunkar)
- 0009337: [Spec] Clarify the expected content of the EstablishConnections outputs in case of aborting a multi-step process with roll-back. (Georg Biehler)
- 0008874: [Spec] When and where to provide preconfigured DataSets (Paul Hunkar)
- 0009229: [Spec] Notation of Graphic unclear in new figure Figure 36 – Command sequence illustration (Paul Hunkar)
- 0009314: [Spec] Improve the Description of the 'Modify' Attribute in Annex F (Paul Hunkar)
- 0009156: [Spec] Missing behaviour in Table 144 – ConnectionEndpointConfigurationResultDataType (Georg Biehler)
- 0009157: [Spec] Detection of changes to a ConnectionConfigurationSet (Georg Biehler)
- 0008790: [Spec] Preconfigured data sets not part of CCS (Georg Biehler)
- 0009102: [Spec] Capability for Asset Verficiation Modes (Paul Hunkar)
- 0009100: [Spec] ConnectionManager and initiating Application (Georg Biehler)
- 0008789: [Spec] Need standard file format for persistence of CCS (Georg Biehler)
- 0009113: [Spec] Need some text for vendor specific processing of CCS (Georg Biehler)
- 0009092: [Spec] Capabilities of the ConnectionManager (Georg Biehler)
- 0009050: [Spec] Need to add some text to part 81 regarding Hostname and address (Paul Hunkar)
- 0009098: [Spec] Verification Methods clarification (Paul Hunkar)
- 0008808: [Spec] Part 81 needs examples/clarification for preconfigured DataSets at AC level (Paul Hunkar)
- 0008971: [Spec] Description of DescriptorIdentifier should state it points to the OPC website (Paul Hunkar)
- 0008643: [Spec] Editorial: The OPC UA term Reference is incorrectly not capitalized in multiple locations (Bob Lattimer)
- 0009042: [Spec] clarify that FunctionalEntities do not have to be a subtype of FunctionalEntityType (Paul Hunkar)
- 0008921: [Spec] Configuration of SecurityGroups and PushTargets for ConnectionManager (Georg Biehler)
- 0008873: [Spec] Usage of strings as references (Georg Biehler)
- 0008941: [Spec] Errors in CCS related Figures (Georg Biehler)
- 0008980: [Spec] Wrong reference in: table 10 - AssetVerificiationResults VerificationResult StatusCodes (Georg Biehler)
- 0008680: [Spec] Editorial issues in figures: 42, E.22, E.23 (Paul Hunkar)
- 0008546: [Spec] FxAssetType - Create Interface for the the folder "Connectors" (Paul Hunkar)
- 0008732: [Spec] Description of the starting point of a RelativePath is missing for the TranslationTable. (Paul Hunkar)
32 issues View Issues
Part 82: UAFX Networking - Change Log
Released 2023-09-20
- 0009360: [Spec] Update the reference to IEEE 802.1Q to the 2022 edition. (Bob Lattimer)
- 0009359: [Spec] Add references to term definitions from external documents. (Bob Lattimer)
- 0009344: [Spec] Reconcile Terms between Part 82 and 60802. (Bob Lattimer)
- 0009148: [Spec] Add list of what could supported in a network containing UAFX Stations, e.g. number of UAFX Stations (Bob Lattimer)
- 0009147: [Spec] Add description of the use of DHCP in a network supporting UAFX devices (Bob Lattimer)
- 0009106: [Spec] mDNS responder support needs to be added to Part 82 (Bob Lattimer)
- 0009105: [Spec] Host name resolution using DNS is needed (Bob Lattimer)
- 0008669: [Spec] The descriptions of UAFX Station are inconsistent (Bob Lattimer)
8 issues View Issues
Part 83: UAFX Offline Engineering - Change Log
Released 2023-09-20
- 0009264: [Spec] Invalid characters are used in Annex J "DescriptorInfo XML Schema" and Annex K "OpcUaLibInfo Schema" (Todd Snide)
1 issue View Issues
Part 84: UAFX Profiles - Change Log
Released 2023-09-20
- 0009354: [Spec] Mandatory variable AggregatedHealth is aggregating optional variables DeviceHealth and OperationalHealth. (Bob Lattimer)
- 0009107: [Spec] DNS for host name resolution and mDNS for responder support need to be added to the UAFX Controller Profile. (Bob Lattimer)
- 0008875: [Spec] Descriptor must include information describing all OPC Foundation capabilities implemented in the product. (Bob Lattimer)
- 0009172: [Spec] New CU needed for the ConnectionManagerConfigurationType support in the UAFX ConnectionManager Facet (Bob Lattimer)
- 0008530: [Spec] Require Product Descriptor in the UAFX Controller Profile (Bob Lattimer)
- 0008783: [Spec] FxAssetType - Create Interface for the folder "Connectors" (Bob Lattimer)
- 0008632: [Spec] Username/Password support mandated by UAFX Controller Server Profile (Greg Majcher)
- 0009134: [Spec] Add CU for support of physical network interface Objects (Bob Lattimer)
- 0009133: [Spec] CUs and Profiles needed for Offline functionality (Bob Lattimer)
- 0008807: [Spec] UAFX Asset SoftwareUpdate should not require support of FxAsset (Bob Lattimer)
- 0008531: [Spec] Add Conformance Units and Profiles that Engineering Tools can import, process and export Descriptors (Bob Lattimer)
- 0008782: [Spec] Change UAFX SKS SetSecurityKeys to PubSub SKS SetSecurityKeys (Bob Lattimer)
- 0008446: [Spec] Recommendation - use different wording for "reference" in IFunctionalEntity OutputData and InputData (Bob Lattimer)
- 0008445: [Spec] CU ConnectionEndpoint Base - Add subtype into the description (Bob Lattimer)
14 issues View Issues
UAFX Nodeset - Change Log
Released 2023-09-20
- 0009258: [Documentation Errata] description string in nodeset have various problems (Paul Hunkar)
- 0009257: [Implementation Bug] ConnectionManagerType->ConnectionConfigurationSets->ConnectionConfiguration->Connection->Endpoint1 (Paul Hunkar)
- 0008693: [Implementation Bug] Wrong ArrayDimensions of Elements field of the DataType PortableRelativePath (Paul Hunkar)
- 0008323: [Spec] Missing mechanism to indicate which connection types (uni, uni+HB, bi-dir) are supported (Paul Hunkar)
- 0008314: [Spec] ComponentCapabilities should be a mandatory folder in the AutomationComponent (Paul Hunkar)
- 0009230: [Implementation Bug] opc.ua.fx.cm.nodeset2.xml have some nodeid with the same 'BrowseName' in the same path of UAFX-1.00.00-2022-10-15 (Paul Hunkar)
- 0009218: [Implementation Bug] New duplicate node in the 1.02 CM namespace (Paul Hunkar)
- 0008186: [Spec] HasAutomationComponent ReferenceType not need can be removed (Paul Hunkar)
- 0008711: [Spec] Wrong ValueRank in AC-NodeSet (Paul Hunkar)
9 issues View Issues